Friday, June 18, 2010

Location map for Interplay 2010 - Penang


Eastin Hotel Penang1 Solok Bayan Indah, Queensbay11900 Bayan Lepas, Penang, MalaysiaTel : +604-612 1111Fax : +604-612 1199Email us : info.pg@eastin.com


Friday, June 11, 2010

Interplay Tour 2010 Itenary

Date & Venue as follows:

28 June 2010 - Johor Bahru, Mutiara Hotel
30 June 2010 - Kuala Lumpur, Dorsett Subang
02 July 2010 - Penang Island, Eastin Hotel


Daily Itenary as follows:

0930~1000 : Registration
1000~1045 : Welcome Speech & Product Information
1045~1100 : Tea Break
1100~1230 : Application Examples
1230~1330 : Lunch
1330~1500 : Application Examples
1500~1515 : Tea Break
1515~1545 : Application Examples
1545~1645 : Q&A
1700 : End of Interplay Tour 2010

Duration & Picked Topics:

30min - Investment Protection
20min - Intuitive Fast Learning
30min - Reusability
20min - Simple and Fast Servicing
15min - Openess
30min - PID Control Technology
20min - Communication
30min - Tips & Tricks

Monday, May 31, 2010

S7-200 PLC for UMS Biotech Lab Waste Treatment Plant
















Beside enabling the plant to be operate in auto condition. The installation of S7-200 couple with TD-200 & conventional mimic provide the following benefits to operators:


- Plant process variable can be change easily via TD200.
- Plant operating errors can be display at TD200.
- Plant component status can be display at 2 tone LED mimic.

A low cost implementation that optimize enclosure size & minimize usage of relays & timers.

_____________________________________________________________________


This page is currently under construction
Please stay tune for more updates!











Wednesday, December 2, 2009

Using EM277 to test S7-200 system with only 1 port

Step 1 - Update to Microwin 4.0 to SP7 (http://support.automation.siemens.com/WW/view/en/33005232).

Step 2 - Connect the PPI cable to EM277

Step 3 - Access via Profibus, the PG/PC interface has to be configured to "S7ONLINE --> PROFIBUS". For example CP5611 (Profibus). Then in properties "mark" "Only Master on the Bus", select address and baud rate should be bigger then 187kbaud.

Step 4 - You are online & connected to the S7-200 system with only 1 port.

Tuesday, October 6, 2009

S7-200 in Power Plant

















The deployment was successfully carry out in Sept 2009.

In this installation, S7-200 PLC act as a data collector, process control centre & interface device between 1 touchscreen + 1 SCADA workstation.

Communication between SCADA workstation ( at Main Control Room ) with S7-200 ( at Local Control Panel, WWTP ) is via WiFi.

This installation exibit the agile, compact & flexible features of low cost S7-200!












Availability of S7-1200 PLC in Malaysia, please contact us!

We are please to inform that following units of S7-1200 is available for local demo / testing:

# CPU1214c - 2 units
# CM1241, RS485 - 1 unit
# SM1234, AI/AQ - 1 unit

S7-1200 has built-in tracebility functions for OEMs / SIs / END-USERs who requires low cost PLC that comply to GAMP 4 environments!