Monday, November 30, 2015

DECEMBER 2015 PROMOTION



UPDATE 01 DECEMBER 2015

------------------------------------------------------------------------
#  Application example
------------------------------------------------------------------------

1. Remote control of S7-1200 RTU with PCS 7 TeleControl (IEC protocol)
 (11/13/2015) [109475749]

   Technological plants can stretch over large expanses, especially in
   the water and waste water sectors. Storm water tanks may be
   connected to a central sewage plant through a channel system
   spanning kilometers. Remote control systems such as PCS 7
   TeleControl integrate such remote terminal units directly into the
   high-level control system.
For products:6ES7658-7JX18-0YA5,

   6ES7652-5CX18-0YK5, 6G...

   more
   => CLICK HERE
------------------------------------------------------------------------

2. Library of general functions for STEP 7 (TIA Portal) and S7-1200 /
   S7-1500
 (11/19/2015) [109479728]

   The library "LGF (Library of general functions)" contains
   additional functions for STEP 7 (TIA Portal)
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

3. PRONETA 2.3.0.19 Commissioning and Diagnostics Tool for PROFINET
11/23/2015
ID:67460624

PRONETA is a free tool for the analysis and configuration of PROFINET networks with special support for ET 200 distributed IO. The IO Test provides quick and comfortable examination and documentation of a plant's wiring.
For products:6ES7153-2DA80-0XB0, 6ES7143-4BF50-0AA0, 6E...



4. Expanding an Existing SINAUT Plant by S7-1200 Stations with CP 1243-8 IRC
11/25/2015
ID:109479747

In existing SINAUT plants with SIMATIC S7-300/400 and the respective TIM modules for remote transmission, S7-1200 stations can also be integrated using CP 1243-8 IRC.
For products:6ES7217-1AG40-0XB0, 6NH7800-4BA00, 6ES7317...



5. Programming Guideline and Programming Styleguide for S7-1200 and
   S7-1500
 (11/24/2015) [81318674]

   To create an optimal program regarding technical possibilities and
   consistency, it is recommended to use the programming guideline and
   programming styleguide for S7-1200/1500.
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

6. Safety Applications with S7-1200 FC CPU
 (11/25/2015) [109478932]

   The document contains a total of 30 scenarios for safety door and
   emergency stop applications. An
   F-block for the direct use of an S7-1200 FC CPU is available to you
   for each scenario. In addition to the easy use of the S7-1200 FC
   CPU, the document also explains what has to be considered to
   achieve a specific PL/SIL.
For products:6ES7214-1AF40-0XB0,

   6ES7215-1AF40-0XB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

7. CANopen with SIMATIC S7
 (11/23/2015) [109479771]

   Integration of CANopen devices into the SIMATIC S7 automation
   world.
For products:6ES7151-7AA13-0AB0, 6ES7217-1AG40-0XB0,

   6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

------------------------------------------------------------------------
#  Download
------------------------------------------------------------------------

16. Firmware download V1.2.18 CP 1243-1 IEC and CP1243-1 DNP3
 (11/20/2015) [109481096]

   Firmware download V1.2.18 CP 1243-1 IEC and CP1243-1 DNP3
For

   products:6GK7243-1JX30-0XE0, 6GK7243-1PX30-0XE0

   more
   => CLICK HERE

------------------------------------------------------------------------
#  Manual
------------------------------------------------------------------------

36. Programming Guideline for S7-1200/1500
 (11/24/2015) [90885040]

   11/2015, Programming manual
For products:6ES7822-1AA03-2YA6,

   6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE

------------------------------------------------------------------------

41. SIMATIC S7-1200 Update to the S7-1200 System Manual, edition
   03/2014
 (11/17/2015) [89851659]

   Product Information
For products:6ES7274-1XF30-0XA0,

   6ES7231-4HF30-0XB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
42. SIMATIC S7-1200 Update to the S7-1200 System Manual, edition
   06/2015
 (11/23/2015) [109478148]

   11/2015, Product information, A5E03929122-AJ
For

   products:6ES7217-1AG40-0XB0, 6ES7212-1AE40-0XB0, 6E...

   more
   => CLICK HERE

Monday, November 16, 2015

IMPORTANT UPDATE 17 NOVEMBER 2015

PLEASE TAKE NOTE! PLEASE DISABLE AUTOMATIC WINDOWS UPDATE to avoid Windows10 to automatically install. This is to avoid INTERRUPTION to your current running system OR programming progress!

Please read for more information at Microsoft's Official Blog
( http://blogs.windows.com/windowsexperience/2015/10/29/making-it-easier-to-upgrade-to-windows-10/ )


Sunday, November 1, 2015

UPDATE 02 NOVEMBER 2015

------------------------------------------------------------------------
#  Application example
------------------------------------------------------------------------

1. Migration of plants in SIMATIC (TIA Portal) - Visualization
 (10/27/2015) [76878921]

   A certain amount of know-how is required for migrating to new
   systems. Siemens supports you with many tools and other aids to get
   successfully into the TIA Portal and the new SIMATIC
   components.
For products:6AV6613-1XA01-1CE0,

   6AV2107-0GB00-0BB0, 6A...

   more
   => CLICK HERE
------------------------------------------------------------------------
2. Example blocks for WinCC V7 and STEP 7 V13 (TIA Portal) for S7-1200
   and S7-1500 in SCL
 (10/27/2015) [31624179]

   This documentation shows how WinCC V7.3 SE and TIA Portal STEP 7
   Professional V13 SP1 with example blocks is used for the solution
   of an technological automation task.
For

   products:6ES7211-1HD30-0XB0, 6ES7217-1AG40-0XB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
3. Migration of plants with SIMATIC (TIA Portal) - Controllers
 (10/28/2015) [83557459]

   A certain amount of know-how is required for migrating to new
   systems. Siemens supports you with many tools and other aids to get
   successfully into the TIA Portal and the new SIMATIC
   components.
For products:6ES7413-2XG00-0AB0,

   6ES7414-2XJ00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

10. Configuration and application of PROFINET I-Device function
 (10/28/2015) [109478798]

   This entry explains the I-Device function and gives an overview of
   the various tasks that can be realized with it. These functions are
   explained in configuration and application examples.
For

   products:6ES7317-2FJ10-0AB0, 6ES7317-2FK14-0AB0, 6E...

   more
   => CLICK HERE

------------------------------------------------------------------------

1. PRONETA 2.2.0.18 Commissioning and Diagnostics Tool for PROFINET    10/21/2015
ID:67460624

During the setup phase of a PROFINET network, the correct configuration and wiring of the distributed IO is to be checked even before CPUs are integrated.
For products:6ES7153-2DA80-0XB0, 6ES7143-4BF50-0AA0, 6E...


=> CLICK HERE

------------------------------------------------------------------------
#  FAQ
------------------------------------------------------------------------

17. TIA Portal - An Overview of the Most Important Documents and Links
   - Safety
 (10/30/2015) [90939626]

   This site gives you an overview of the most important documents and
   links for the TIA Portal. Both newcomers and experienced TIA Portal
   users have an entry here to the essential information about the TIA
   Portal.
For products:6AV2103-0HA02-0UA0, 6AV2104-2FH03-0BJ0,

   6A...

   more
   => CLICK HERE
------------------------------------------------------------------------
18. Which communication services are supported by the CPUs with
   integrated PROFINET interface, the S7 software controller and by
   the WinAC RTX via Industrial Ethernet?
 (10/26/2015) [18909487]

   The table below shows, which devices support which communication
   services.
For products:6ES7317-7TK10-0AB0, 6ES7317-2FJ10-0AB0,

   6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
25. TIA Portal - An Overview of the Most Important Documents and Links
   - Controller
 (10/30/2015) [65601780]

   This site gives you an overview of the most important documents and
   links for the TIA Portal. Both newcomers and experienced TIA Portal
   users have an entry here to the essential information about the TIA
   Portal.
For products:6AV2107-0GB00-0BB0, 6AV2103-0HA02-0UA0,

   6A...

   more
   => CLICK HERE
------------------------------------------------------------------------
27. How do you use a hardware-independent clock with adjustable
   frequency in STEP 7 (TIA Portal)?
 (10/26/2015) [87507915]

   You want to use a clock that is hardware-independent, is processed
   synchronously and whose frequency can be set individually.
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
34. Which rules have to be followed in STEP 7 V5.x and the TIA Portal
   when assigning the PROFINET device name?
 (10/26/2015) [109479534]

   The PROFINET device name is defined in the standard IEC 61158-6-10.
   To be able to communicate with PROFINET devices they have to be
   assigned names. These names are the device names in the Hardware
   Configuration. These device names must comply with the PROFINET
   name convention.
For products:6ES7822-1AA03-2YA6,

   6ES7810-4CC10-0KA5, 6E...

   more
   => CLICK HERE