Monday, June 13, 2016

UPDATE 13 JUNE 2016

------------------------------------------------------------------------
#  Application example
------------------------------------------------------------------------
5. Sending and Receiving SMS Messages via a SCALANCE M Router
 (5/23/2016) [54361177]

   A SIMATIC S7-1200/1500 station is to automatically send important
   information about the plant status, alarm messages or warnings to
   mobile service personnel using the SCALANCE M874/M876
   router.
For products:6GK5874-3AA00-2AA2,
6GK5876-3AA02-2BA2

   more
   => CLICK HERE
------------------------------------------------------------------------

1. Inter-Station Communication between S7-1200 Stations Using TCSB V3
   via CP 1242-7 V2
 (5/17/2016) [58099765]

   An automation infrastructure contains S7-1200 substations that are
   to exchange data in a cost-effective way on a wireless
   basis.
For products:6GK7242-7KX31-0XE0


   more
   => CLICK HERE
------------------------------------------------------------------------
2. Data communication between S7-1200 stations and TeleControl Server
   Basic V3 via CP 1242-7 V2 and CP1243-1
 (5/17/2016) [39863979]

   An automation infrastructure contains S7-1200 substations which
   shall communicate cost-effectively with a central station via the
   mobile communications network or via Ethernet. The TeleControl
   Server Basic V3 software is installed in the central
   station.
For products:6GK7242-7KX31-0XE0, 6GK7243-1BX30-0XE0


   more
   => CLICK HERE
------------------------------------------------------------------------
3. Example Blocks for WinCC (TIA Portal) and STEP 7 (TIA Portal) for
   S7-1200 and S7-1500 with SCL
 (5/17/2016) [66839614]

   The function scope of WinCC (TIA Portal) and STEP 7 (TIA Portal)
   can be expanded by technology blocks.
For

   products:6AV2124-1MC01-0AX0, 6ES7513-1AL00-0AB0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
4. Communication between two LOGO! Controllers by means of LOGO! CMR
   and SMS
 (5/3/2016) [109483740]

   In order to supply a remote, elevated region with water, a water
   reservoir is installed and filled by a pump in the valley. The pump
   is to be switched on and off, depending from the filling level of
   the water reservoir.
For products:6EP1331-1SH01,

   6ED1052-2MD00-0BA6,...

   more
   => CLICK HERE
------------------------------------------------------------------------
23. How do you connect a PT100 sensor to the LOGO! analog expansion
   module AM2 PT100 or AM2 RTD?
 (4/25/2016) [23671451]

   To the LOGO! analog expansion module AM2 PT100 or AM2 RTD you can
   connect sensors with 2-conductor, 3-conductor or 4-conductor
   connections.
For products:6ED1055-1MD00-0BA1,

   6ED1055-1MD00-0BA2,...

   more
   => CLICK HERE
------------------------------------------------------------------------
24. With LOGO! how can you configure switching thresholds for analog
   signals?
 (5/4/2016) [24003057]

   Depending on the application you have two different function blocks
   (analog comparator and analog watchdog) to choose from in LOGO!
   SoftComfort for defining switching thresholds.
For

   products:6ED1058-0BA02-0YA0, 6ED1058-0BA02-0YA1,...

   more
   => CLICK HERE
------------------------------------------------------------------------
25. How do you transform digital pulses into an analog value with
   LOGO!?
 (4/27/2016) [50083269]

   Cyclic determination of the number of the digital pulses in a
   defined time period and read-out as an analog value via an analog
   network input.
For products:6ED1058-0BA02-0YA1,

   6ED1058-0CA02-0YE1,...

   more
   => CLICK HERE
------------------------------------------------------------------------
26. How do you change the password for the change of LOGO! mode?
 (4/28/2016) [109482389]

   LOGO! demands a password when you want to change from OP mode to
   Admin mode. Here we show how to change this password.
For

   products:6ED1052-2FB00-0BA8, 6ED1052-1HB00-0BA8,...

   more
   => CLICK HERE
------------------------------------------------------------------------
27. How do you monitor a connection between two LOGO! 8 basic modules?
 (4/28/2016) [109483102]

   To make sure that data is exchanged between two LOGO! basic modules
   you have to monitor the connection.
For

   products:6ED1052-1HB00-0BA8, 6ED1052-1FB00-0BA8,...

   more
   => CLICK HERE
------------------------------------------------------------------------
28. Which LOGO! device series can you use for a program created with
   LOGO!Soft Comfort V8?
 (5/4/2016) [109483221]

   With LOGO!Soft Comfort V8 you can also create control programs for
   previous LOGO! device series. However, you cannot load any programs
   that use the new special functions or the new special function
   parameters into LOGO! basic modules previous to device series
   0BA8.
For products:6ED1058-0BA08-0YA1


   more
   => CLICK HERE

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.