# FAQ
------------------------------
9. In STEP 7 (TIA Portal) how do you calculate from an arbitrary
number of read-in values a current arithmetic average value for
the S7-1200/S7-1500?
(8/31/2015) [39333120]
For every change of input value the FB "Average" calculates a new
sum of the read-in values and from them the current arithmetic
average value.
For products: 6ES7822-1AA03-2YA6,
6ES7513-1AL00-0AB0, 6E...
more
=> CLICK HERE
------------------------------
10. In STEP 7 (TIA Portal) how do you convert from degrees to radians
and vice versa for the S7-1200/S7-1500?
(8/31/2015) [41994741]
For processing the trigonometric functions sine, cosine and tangent
with STEP 7 (TIA Portal) you must specify degrees in
radians.
For products: 6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0,
6E...
more
=> CLICK HERE
------------------------------
11. In STEP 7 (TIA Portal) how do you copy memory areas and structured
data from one data block to another?
(8/31/2015) [42603881]
With S7-1200/S7-1500, if you want to copy memory areas, in STEP 7
(TIA Portal) you use the instructions "MOVE_BLK", "UMOVE_BLK",
"MOVE" and "MOVE_BLK_VARIANT".
For products:
6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...
more
=> CLICK HERE
------------------------------
14. Why can you not access the web server of the S7-1200 CPU when you
upgrade the firmware from V3.0 or V4.0 to V4.1?
(8/31/2015) [109476758]
In some cases, after upgrading the firmware in the S7-1200 CPU
modules it is not possible to access the web server.
For
products: 6ES7822-1AA03-2YA6, 6ES7211-1HD30-0XB0, 6E...
more
=> CLICK HERE
------------------------------
# Application example
------------------------------
1. Demo projects for HMI operator panels under WinCC V13 (TIA Portal)
for Basic Panels (2nd generation), Comfort Panels and Mobile
Panels (2nd generation)
(9/7/2015) [96003274]
On this page you find the respectively current demo projects that
are provided for the use of different HMI operator panels.
For
products: 6AV2104-2FH03-0BJ0, 6AV2103-0XA03-0AH5, 6A...
more
=> CLICK HERE
------------------------------
3. Remote control of S7-1200 RTU with PCS 7 TeleControl (IEC protocol)
(9/8/2015) [109475749]
Technological plants can stretch over large expanses, especially in
the water and waste water sectors. Storm water tanks may be
connected to a central sewage plant through a channel system
spanning kilometers. Remote control systems such as PCS 7
TeleControl integrate such remote terminal units directly into the
high-level control system.
For products: 6ES7658-7JX18-0YA5,
6GK7243-1PX30-0XE0, 6E...
more
=> CLICK HERE
------------------------------
# Product note
------------------------------
14. Announcement product phase-out for LOGO! 7 (0BA7)
(9/8/2015) [109479478]
The two LOGO! 7 logic modules will be declared discontinued on
October 1, 2015:
For products: 6ED1052-1FB00-0BA7,
6ED1052-1MD00-0BA7, 6E...
more
=> CLICK HERE
------------------------------
15. SIPLUS extreme – Announcement of product phase-out for SIPLUS LOGO!
V7 (*BA7)
(9/10/2015) [109479525]
From the SIPLUS extreme product range, the product phase-out named
below will take place for SIPLUS LOGO! on October 1, 2015. The
SIPLUS extreme product range features refined components on the
basis of Siemens Digital Factory standard products.
For products: 6AG1052-1FB00-2BA7, 6AG1052-1MD00-2BA7
more
=> CLICK HERE