Friday, October 11, 2013

OCTOBER v1 UPDATE

FAQ


+ TIA Portal - An Overview of the Most Important Documents and Links (2013-08-05) [65601780]
   TIA Portal The new Automation Framework for SIMATIC This site gives you an overview of the most important documents and links for the TIA Portal.
   => 
CLICK HERE

+ How in STEP 7 (TIA Portal) can you access the unstructured data
types bit-by-bit, byte-by-byte or word-by-word and symbolically?
   Description In the case of S7-1200 (as from firmware V2.0) and S7-1500 you have the option of accessing bit-by-bit the tags of the Byte, Word and DWord data types. For this you need STEP 7 V11+SP1+Update (or higher). The partitioning of a memory area (Byte or Word, for example) into a smaller memory area (Bool, for
   example) is also called memory slicing. Fig. 01 shows the symbolic bit, byte and word access to operands. ...
   => CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 2 -  User Defined Webpage (2013-08-16) [75311612]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIAPortal)  SIMATIC S7-1200: AT 2 - User Defined Webpage...
   => 
CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 8 - Simple AS-Interface (2013-08-16) [75311929]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIA Portal)  SIMATIC S7-1200: AT 8 - Simple AS-Interface...
   => 
CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 3 -  GPRS to SMS (2013-08-16) [75312320]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIA Portal)  SIMATIC S7-1200: AT 3 - GPRS to SMS...
   => 
CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 9 - SIMATIC App (2013-08-16) [75312637]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIA Portal)  SIMATIC S7-1200: AT 9 - SIMATIC App...
   => 
CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 5 - HMI to SCADA (2013-08-16) [75312933]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIA Portal)  SIMATIC S7-1200: AT 5 - HMI to SCADA...
   => 
CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 1 - Simple Movements (2013-08-16) [75313272]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIA Portal)  SIMATIC S7-1200: AT 1 - Simple Movements...
   => 
CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 4 - Simple HMI (2013-08-16) [75313273]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIA Portal)  SIMATIC S7-1200: AT 4 - Simple HMI...
   => 
CLICK HERE

 + Automation Tasks in 10 minutes or less SIMATIC S7-1200: AT 6 - Distributed Networks (2013-08-16) [75315170]
   Solve Automation Tasks efficiently with SIMATIC and STEP 7 (TIA Portal)  SIMATIC S7-1200: AT 6 - Distributed Networks...
   => 
CLICK HERE
+ Which panels and flat screens does Siemens currently offer for hazardous areas with potentially explosive atmosphere (Ex2/22)?
   Product Notes This entry contains all the SIMATIC HMI panels, panel PCs and flat screens that Siemens is currently offering for hazardous areas with potentially explosive atmosphere (Ex2/22).
   => 
CLICK HERE

  + What is the meaning of the system constants in STEP 7 (TIA Portal) with S7-1200/1500? (2013-08-19) [78782835]
   Description Unlike S7-300/400, in which the hardware and software components are identified through logical addresses or diagnostics addresses, in S7-1200/1500 the identification is over the system constants. All the hardware and software components (like interfaces, modules, OBs, ...) of the S7-1200/1500 have their own
  system constants. The system constants are generated automatically when the device configuration is created for the central and remote IOs. ...
   => 
CLICK HERE

  + How do you import variables from MS Excel into a PLC data type in STEP 7 (TIA Portal)? (2013-08-19) [78786898]
   Description In STEP 7 (TIA Portal) you can import your variables from Microsoft Excel into your PLC data type. Prepare your data in Microsoft Excel as shown in Fig. 01. Then proceed as follows to import your variables to STEP 7 (TIA Portal). In Excel you mark all the cells that include your variables and save the data in the
   buffer memory using the key combination 'CTRL+C'. ...
   => 
CLICK HERE
 
 + How in STEP 7 (TIA Portal) can you access a network folder in a VMWare? (2013-08-19) [78788417]
   Description If you install STEP 7 (TIA Portal) V12 on a VMware and store the project on a shared drive, under certain circumstances it might happen that you have no write rights for your program. After opening your project you get this message: 'Open project (0080:000014) - the memory area is write-protected. ...
   => 
CLICK HERE
 + How do you configure cyclic data exchange between an S7-1200 CPU (with CP 1242-7) and the Telecontrol server? (2013-06-18) [73941299]
   Description The 'Cyclic data exchange' function is used to send data cyclically from the CP 1242-7 to the Telecontrol server. The CP 1242- 7 does not send the data automatically to the Telecontrol server but only when the Telecontrol server requests it (read/fetch). ...
   => 
CLICK HERE

 + What’s important for a direct Modbus connection between a SIMATIC HMI and a SIWAREX WP231? (2013-06-20) [75340699]
Question: What’s important for a direct Modbus connection between a SIMATIC HMI and a SIWAREX WP231? 

    => CLICK HERE

 + In STEP 7 (TIA Portal) V11, how do you download a project into an S7-1200 CPU when you have previously downloaded with STEP 7 V12?  (2013-06-19) [74930238]
   Description In STEP 7 (TIA Portal) V11 you cannot download a project into an S7-1200 CPU when you have previously downloaded  with STEP 7 V12. The download procedure is aborted with an internal system error. ...
   => 
CLICK HERE

 + Why does the start of the executable file take 30 to 40 seconds when installing STEP 7 (TIA Portal)? (2013-06-20) [75160695]
   Description In some cases the start of the executable file takes 30 to 40 seconds when installing STEP 7 (TIA Portal), which gives the impression that the program is not being executed. The reason for this behavior is that the executable file has a digital signature and the server does not receive an answer from the revocation list over the internet. Right-click the executable file (Start.exe) and open the 'Properties' in the pop-up menu that opens. In the 'Start.exe ...
   => 
CLICK HERE