Tuesday, August 1, 2017

UPDATE 01 AUGUST 2017

------------------------------------------------------------------------
#  Application example
------------------------------------------------------------------------

11. Basic Examples for Open User Communication (OUC)
 (6/28/2017) [109747710]

   By now, TCP/IP-based Open User Communication (OUC) is the standard
   for communication with SIMATIC S7-CPUs.
For

   products:6ES7513-1AL00-0AB0, 6ES7217-1AG40-0XB0,...

   more
   => CLICK HERE
------------------------------------------------------------------------

12. Recording User Activity on a SIMATIC Controller Using a SIEM System
 (6/30/2017) [109748211]

   Modern automation infrastructures are becoming increasingly
   complex. The individual stations and components in the automation
   plant are increasingly networked and develop continuously. Due to
   this deep complexity and networking as well as the standardization,
   certification and regulatory requirements, the issue of industrial
   security is becoming increasingly important.
For

   products:6ES7410-5HX08-0AB0, 6ES7658-...58-....

   more
   => CLICK HERE
------------------------------------------------------------------------
4. Data Communication between S7-1200 and SENTRON PAC3200 via MODBUS
   TCP (Set 22)
 (7/4/2017) [40614428]

   This application example describes the deterministic data exchange
   of a S7-1200 controller with several SENTRON PAC3200 power
   monitoring device via Modbus/TCP. The communication with the
   individual measuring devices takes place successively via a
   connection.
For products:6AV2101-0AA02-0AA5,

   6AV2101-0AA02-0UA0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
8. Working with the TIA Portal Cloud Connector
 (7/5/2017) [109747305]

   The TIA Portal Cloud Connector enables central management of your
   engineering software on a server. From an engineering workstation,
   you can work with TIA Portal (which is installed on a server) via a
   remote desktop connection. For this, the TIA Portal Cloud Connector
   serves as communication tunnel.
For products:6ES7823-1CA00-0YA0


   more
   => CLICK HERE
------------------------------------------------------------------------
4. Toolbox for HMI Projects
 (7/10/2017) [106226404]

   It is often the small tools that make work easier. This entry
   contains some useful tools that you can easily integrate into your
   HMI configuration via libraries. For example, a stopwatch, a file
   explorer or also a calculator, .... The toolbox for HMI projects
   currently offers 28 tools already and is continuously
   expanded.
For

   products:6AV210.-....4-0;6AV2104-....4-0;6AV2105-....3

   more
   => CLICK HERE
------------------------------------------------------------------------
7. Monitoring Machines and Plants with Network Cameras and SIMATIC HMI
   Comfort Panels
 (7/13/2017) [62383298]

   SIMATIC Comfort Panels and the KTP Mobile Panels providing a camera
   control. It shows videos from IP cameras in HMI Runtime.
For

   products:6AV2124-1MC01-0AX0, 6AV2124-0JC01-0AX0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
2. FTP Client Communication with S7-1200/1500
 (7/28/2017) [81367009]

   This entry shows an application solution of how an S7-1500/1200 can
   exchange data with an FTP server as simple FTP client without
   communication processor.
For products:6ES7513-1AL00-0AB0,

   6ES7211-1HD30-0XB0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
4. PRONETA 2.4.0.39 Commissioning and Diagnostics Tool for PROFINET
 (7/25/2017) [67460624]

   PRONETA is a free tool for the analysis and configuration of
   PROFINET networks with special support for ET 200 distributed IO.
   The IO Test can provide support with the quick and comfortable
   examination and documentation of a plant's wiring.
For

   products:6ES7143-4BF50-0AA0, 6ES7322-5GH00-0AB0,...

   more
   => CLICK HERE
------------------------------------------------------------------------


------------------------------------------------------------------------
#  FAQ
------------------------------------------------------------------------

14. Which SNMP requests can the S7-1500 CPUs and S7-1200 CPUs receive
   and reply to?
 (6/30/2017) [79993228]

   The S7-1500 CPUs and S7-1200 CPUs support the transfer of
   management information over the Simple Network Management Protocol
   (SNMP). The S7-1500 CPUs and S7-1200 CPUs can receive and reply to
   SNMP requests?
For products:6ES7211-1HD30-0XB0,

   6ES7217-1AG40-0XB0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
14. Why are USB 3.0 devices recognized by Windows even though the USB
   port is disabled?
 (7/7/2017) [109742381]

   USB 2.0 and USB 3.0 interfaces have to be disabled
   separately.
For products:6AG4112-2....-....,

   6AG4132-2....-....,...

   more
   => CLICK HERE
------------------------------------------------------------------------
18. How do you prevent write access to the outputs of your Modbus slave
   (S7-1500 / S7-1200)?
 (7/7/2017) [109748190]

   The Modbus instructions "MB_SERVER" V4.2 and higher and
   "Modbus_Slave" V3.0 and higher enable you to parameterize the valid
   address area of the outputs to prevent unauthorized access to the
   process image outputs of the Modbus master (via function code 5 or
   15).
For products:6ES7513-1AL00-0AB0, 6ES7217-1AG40-0XB0,...


   more
   => CLICK HERE
------------------------------------------------------------------------
22. What are the requirements for installing STEP 7 (TIA Portal) V14
   SP1?
 (7/5/2017) [50204569]

   The information and links below give you an overview of the general
   requirements for installing STEP 7 (TIA Portal).
For

   products:6ES7822-1..03-.., 6ES7822-0A.03-..,...

   more
   => CLICK HERE
------------------------------------------------------------------------
28. How do you program and parameterize Modbus/TCP communication
   between S7-1500 CPUs and S7-1200 CPUs?
 (7/5/2017) [102020340]

   Modbus/TCP communication between S7-1500 CPUs and S7-1200 CPUs is
   presented. The instructions "MB_CLIENT" and "MB_SERVER" are called
   and parameterized in the user program of the S7-1500 CPU and the
   S7-1200 CPU.
For products:6AG1214-1AG40-4XB0,

   6AG1215-1HG40-4XB0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
31. With LOGO! 8, how do you acquire the measurement data of a SENTRON
   PAC3200 via Modbus TCP/IP?
 (7/5/2017) [109746315]

   With release FS:04, LOGO! 8 supports the Modbus protocol in
   Ethernet TCP/IP networks.
For products:6ED1052-2FB00-0BA8,

   6ED1052-1HB00-0BA8,...

   more
   => CLICK HERE
------------------------------------------------------------------------
24. With WinCC, how can you access tags of the S7-1200 and the S7-1500
   controllers?
 (7/18/2017) [38051469]

   Connections to the controllers S7-1200 and S7-1500
For

   products:6AG1214-1AG40-4XB0, 6AG1215-1HG40-4XB0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
25. What is the power consumption or power dissipation of the SIMATIC
   HMI operator panels?
 (7/18/2017) [44356678]

   With SIMATIC HMI operator panels the power dissipation is only
   insignificantly less than the power consumption.
For

   products:6AG1647-0AE11-4AX0, 6AG1647-0AG11-4AX0,...

   more
   => CLICK HERE
------------------------------------------------------------------------



------------------------------------------------------------------------
#  Manual
------------------------------------------------------------------------

18. LOGO!Power Manual
 (6/30/2017) [109748760]

   06.2017, Equipment Manual, A5E40912965-1-76
For

   products:6EP3310-6SB00-0AY0, 6EP3311-6SB00-0AY0,...

   more
   => CLICK HERE
------------------------------------------------------------------------
51. SIMATIC NET: S7-1200 - TeleControl CP 1243-1
 (6/26/2017) [103948898]

   04/2017, Operating Instructions, C79000-G8976-C365-03
For

   products:6GK7243-1BX30-0XE0

   more
   => CLICK HERE
------------------------------------------------------------------------
52. SIMATIC NET: S7-1200 - TeleControl CP 1242-7 GPRS V2
 (6/26/2017) [109476700]

   04/2017, Operating Instructions, C79000-G8976-C311-03
For

   products:6GK7242-7KX31-0XE0

   more
   => CLICK HERE
------------------------------------------------------------------------
53. SIMATIC NET: S7-1200 - TeleControl CP 1243-7 LTE
 (6/28/2017) [109476704]

   04/2017, Operating Instructions, C79000-G8976-C381-03
For

   products:6GK7243-7SX30-0XE0, 6GK7243-7KX30-0XE0

   more
   => CLICK HERE
------------------------------------------------------------------------
54. CP1243-1 DNP3 Device Profile
 (6/26/2017) [109748510]

   04/2016, Function Manual, -
For products:6GK7243-1BX30-0XE0


   more
   => CLICK HERE
------------------------------------------------------------------------
55. SIMATIC S7-1200 CP 1243-1 V3.0 Protocol IEC 60870-5-104 -
   Interoperability list V1.7
 (6/26/2017) [109748513]

   05/17, Function Manual, -
For products:6GK7243-1BX30-0XE0


   more
   => CLICK HERE
------------------------------------------------------------------------
56. License Conditons and Copyright Notices CP 1243-1, CP 1243-1 PCC
 (6/26/2017) [109748524]

   05/17, Readme, -
For products:6GK7243-1BX30-0XE0


   more
   => CLICK HERE
------------------------------------------------------------------------
57. License Conditions and Copyright Notices CP 1242-7 GPRS V2 und CP
   1243-7 LTE
 (6/28/2017) [109748638]

   05/2017, Readme, -
For products:6GK7242-7KX31-0XE0


   more
   => CLICK HERE
------------------------------------------------------------------------
32. Catalog ST 70: Products for Totally Integrated Automation-SIMATIC
 (7/4/2017) [109744167]

   2017, Catalog
For products:6ES7143-4BF50-0AA0,

   6ES7340-1BH02-0AE0,...

   more
   => CLICK HERE
------------------------------------------------------------------------



------------------------------------------------------------------------
#  Product note
------------------------------------------------------------------------

53. Type discontinuation SIMATIC S7-200 products
 (7/18/2017) [109749165]

   Effective immediately, the products listed below will be
   discontinued (milestone PM 410) and only available as spare parts
   from our spare parts service. Orders and deliveries as a new part
   are no longer possible.
 
For products:6ES7241-1AA22-0XA0, 6ES7298-2DS23-0XA0,...


   more
   => CLICK HERE
------------------------------------------------------------------------