Tuesday, December 29, 2015

IMPORTANT ANNOUNCEMENT 29DEC2015

Dear Valued Customers,
The IndustryMall will be under maintenance from 31 December 2015 until 04 January 2016. At this time the Industry Mall will not have prices. The system will resume on 05 January 2016.
Please take note that there is a Price change from 05January 2016 onwards.

UPDATE 29 DECEMBER 2015

------------------------------------------------------------------------
#  Application example
------------------------------------------------------------------------

1. Getting Started SIMATIC S7-1500
 (12/10/2015) [78027451]

   Introduction to the new SIMATIC S7-1500 controller family
For

   products:6ES7522-1BF00-0AB0, 6ES7505-0RA00-0AB0, 6E...

   more
   => CLICK HERE
 
2. Library with program examples for TIA Portal instructions
 (12/4/2015) [109476781]

   The “Sample Library for Instructions” offers you a selection of
   different examples of how the instructions can be used in TIA
   Portal STEP 7.
For products:6ES7822-1AA03-2YA6,

   6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
 
3. TIA Portal V12 Library with screens for Controlling a SINAMICS G120 Drive with a SIMATIC S7-1200/300/400 Controller
12/17/2015
ID:63042779

A SIMATIC S7-1200/300/400 controller should be control a SINAMICS G120 drive via PROFINET or PROFIBUS DP.
For products:6ES7413-2XG00-0AB0, 6SL3244-0BB13-1FA0, 6E...
   =>CLICK HERE
 
4. Industrial Networks Education - Success through training
Digitalization is the top topic in industry. The merging of the virtual and real worlds promises significant growth. To be able to successfully follow the path to the "future of industry", powerful industrial networks based on proven standards are required  – as well as the know-how to plan and realize these networks and connect them to a corporate network. With Industrial Networks Education, Siemens offers target-oriented training courses on the topic of industrial networks. Based on the three pillars Switching and Routing, Security, and Wireless LAN, participants obtain comprehensive network knowledge, which can be documented with a certificate on request. 

5. Totally Integrated Automation in practice
--> Safe ride on Italy's fastest roller coaster (Video)
The company Inautec develops controllers for roller coasters. Fail-safe controllers and drives from Siemens are used. In an emergency, the cars are safely brought to a halt. Maximum passenger safety is guaranteed.
--> Safety in machine tools (Video)
Weiler Werkzeugmaschinen GmbH relies on system-integrated safety technology from Siemens. In contrast to conventional safety solutions, the response time, wiring costs and the space required in the control cabinet can be reduced.
--> Conveyor technology
Drives technology for conveying applications in automotive boydy construction needs to be robust and reliable.  As well failsafe, communication capable, energy- and cost efficient.  Therefore the automobile manufacturer VW in Emden, Germany  realized the conveyors in the new body construction hall with new distributed inverters and motor starters.
--> Siemens Industry Reference Center with many more interesting articles, including:
 
6. Master-Slave Communication via UDP Broadcast
 (12/22/2015) [20983558]

   A master shall be able to send a data record to several slaves
   quickly and simultaneously to initiate a quasi-synchronous
   reaction. This requirement is particular frequent in conveyor and
   transport systems. The number of active slaves shall be flexible,
   and the function of the master be transferrable to other
   stations.
For products:6ES7513-1AL00-0AB0, 6ES7211-1HD30-0XB0,

   6E...

   more
   => CLICK HERE

7. Safety Applications with S7-1200 FC CPU
 (12/21/2015) [109478932]

   The document contains a total of 30 scenarios for safety door and
   emergency stop applications. An
   F-block for the direct use of an S7-1200 FC CPU is available to you
   for each scenario. In addition to the easy use of the S7-1200 FC
   CPU, the document also explains what has to be considered to
   achieve a specific PL/SIL.
For products:6ES7214-1AF40-0XB0,

   6ES7215-1AF40-0XB0, 6E...

   more
   => CLICK HERE
 
------------------------------------------------------------------------
#  Download
------------------------------------------------------------------------
1. Support Packages for the hardware catalog in the TIA Portal (HSP)
 (12/3/2015) [72341852]

   Attached are the latest Support Packages for several TIA Portal
   versions ready for downloading.
For

   products:6AG1231-5PD32-4XB0, 6AG1241-1CH30-5XB1, 3R...

   more
   => CLICK HERE
2. Updates for STEP 7 V13 SP1 and WinCC V13 SP1
 (12/10/2015) [109311724]

   Status Dezember 2015: Update 6
For products:6AV2103-0XA03-0AH5,

   6AV2101-4BB03-0AE5, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
#  Manual
------------------------------------------------------------------------
1. SIMATIC S7-1200 - CP 1243-1 IEC V 1.2 - Protocol IEC 60870-5-104 -
   Interoperability list V1.5
 (11/30/2015) [109481296]

   11/2015, Reference manual
For products:6GK7243-1PX30-0XE0


   more
   => CLICK HERE
 
2. SIMATIC S7-1200 - CP 1243-1 IEC V 1.2 - Protocol IEC 60870-5-104 -
   Interoperability list V1.6
 (12/8/2015) [109481296]

   12/2015, Reference manual
For products:6GK7243-1PX30-0XE0


   more
   => CLICK HERE
3. How can a PLC Program be protected against unauthorized manipulation?
12/21/2015
ID:109481671

This security information lists measures to protect PLC programs by using appropriate PLC protection methods. The features can be used to reduce the likelihood of unauthorized access and configuration changes to automation components.
For products:6ES7413-2XG00-0AB0, 6ES7414-2XJ00-0AB0, 6E...

CLICK HERE
------------------------------------------------------------------------
#  Announcement
------------------------------------------------------------------------
SIPLUS extreme – Product discontinuation for SIPLUS LOGO! upmiter 1.25A (6AG1053-1AA00-2AA0) and SIPLUS S7-300 Upmiter 4A (6AG1305-1AA00-2AA0)
12/15/2015
ID:109481607

From the SIPLUS extreme product range, The product cancellation/discontinuation named below will be announced for the following products with effect from 01 January 2016. The SIPLUS LOGO! upmiter 1.25A (6AG1053-1AA00-2AA0) and SIPLUS S7-300 Upmiter 4A (6AG1305-1AA00-2AA0) SIPLUS extreme product range features refined components on the basis of Siemens Industry standard products.
For products:6AG1305-1AA00-2AA0, 6AG1053-1AA00-2AA0



------------------------------------------------------------------------
#  FAQ
------------------------------------------------------------------------
1. What options are there in STEP 7 (TIA Portal) for backing up
   projects and what is the significance of the backup files of the
   projects?
 (12/18/2015) [92561565]

   STEP 7 (TIA Portal) provides a number of options for backing up
   your project data. The backup files you create of the STEP 7
   projects are intra-system and cannot be used for manual restoration
   of STEP 7 (TIA Portal) projects.
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
2. How do you implement channel diagnostics in the user program of the
   SIMATIC S7-1200/1500?
 (12/15/2015) [109480387]

   This entry provides a function block for diagnosing channel errors
   in the central configuration or in an IO module connected via
   PROFINET IO. This block uses the "RALRM" instruction.
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE

3. How can a PLC Program be protected against unauthorized
   manipulation?
 (12/21/2015) [109481671]

   This security information lists measures to protect PLC programs by
   using appropriate PLC protection methods. The features can be used
   to reduce the likelihood of unauthorized access and configuration
   changes to automation components.
For

   products:6ES7413-2XG00-0AB0, 6ES7414-2XJ00-0AB0, 6E...

   more
   => CLICK HERE

4. What is to do if I want to project, set up and put into circulation
   a legal for trade scale?
 (12/22/2015) [22036987]

   QUESTION: What is to do if I want to project, set up and put into
   circulation a legal for trade scale? ...
For

   products:7MH4900-2AA01

   more
   => CLICK HERE

Tuesday, December 1, 2015

DECEMBER 2015 PROMOTION



UPDATE 01 DECEMBER 2015

------------------------------------------------------------------------
#  Application example
------------------------------------------------------------------------

1. Remote control of S7-1200 RTU with PCS 7 TeleControl (IEC protocol)
 (11/13/2015) [109475749]

   Technological plants can stretch over large expanses, especially in
   the water and waste water sectors. Storm water tanks may be
   connected to a central sewage plant through a channel system
   spanning kilometers. Remote control systems such as PCS 7
   TeleControl integrate such remote terminal units directly into the
   high-level control system.
For products:6ES7658-7JX18-0YA5,

   6ES7652-5CX18-0YK5, 6G...

   more
   => CLICK HERE
------------------------------------------------------------------------

2. Library of general functions for STEP 7 (TIA Portal) and S7-1200 /
   S7-1500
 (11/19/2015) [109479728]

   The library "LGF (Library of general functions)" contains
   additional functions for STEP 7 (TIA Portal)
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

3. PRONETA 2.3.0.19 Commissioning and Diagnostics Tool for PROFINET
11/23/2015
ID:67460624

PRONETA is a free tool for the analysis and configuration of PROFINET networks with special support for ET 200 distributed IO. The IO Test provides quick and comfortable examination and documentation of a plant's wiring.
For products:6ES7153-2DA80-0XB0, 6ES7143-4BF50-0AA0, 6E...



4. Expanding an Existing SINAUT Plant by S7-1200 Stations with CP 1243-8 IRC
11/25/2015
ID:109479747

In existing SINAUT plants with SIMATIC S7-300/400 and the respective TIM modules for remote transmission, S7-1200 stations can also be integrated using CP 1243-8 IRC.
For products:6ES7217-1AG40-0XB0, 6NH7800-4BA00, 6ES7317...



5. Programming Guideline and Programming Styleguide for S7-1200 and
   S7-1500
 (11/24/2015) [81318674]

   To create an optimal program regarding technical possibilities and
   consistency, it is recommended to use the programming guideline and
   programming styleguide for S7-1200/1500.
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

6. Safety Applications with S7-1200 FC CPU
 (11/25/2015) [109478932]

   The document contains a total of 30 scenarios for safety door and
   emergency stop applications. An
   F-block for the direct use of an S7-1200 FC CPU is available to you
   for each scenario. In addition to the easy use of the S7-1200 FC
   CPU, the document also explains what has to be considered to
   achieve a specific PL/SIL.
For products:6ES7214-1AF40-0XB0,

   6ES7215-1AF40-0XB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

7. CANopen with SIMATIC S7
 (11/23/2015) [109479771]

   Integration of CANopen devices into the SIMATIC S7 automation
   world.
For products:6ES7151-7AA13-0AB0, 6ES7217-1AG40-0XB0,

   6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

------------------------------------------------------------------------
#  Download
------------------------------------------------------------------------

16. Firmware download V1.2.18 CP 1243-1 IEC and CP1243-1 DNP3
 (11/20/2015) [109481096]

   Firmware download V1.2.18 CP 1243-1 IEC and CP1243-1 DNP3
For

   products:6GK7243-1JX30-0XE0, 6GK7243-1PX30-0XE0

   more
   => CLICK HERE

------------------------------------------------------------------------
#  Manual
------------------------------------------------------------------------

36. Programming Guideline for S7-1200/1500
 (11/24/2015) [90885040]

   11/2015, Programming manual
For products:6ES7822-1AA03-2YA6,

   6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE

------------------------------------------------------------------------

41. SIMATIC S7-1200 Update to the S7-1200 System Manual, edition
   03/2014
 (11/17/2015) [89851659]

   Product Information
For products:6ES7274-1XF30-0XA0,

   6ES7231-4HF30-0XB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
42. SIMATIC S7-1200 Update to the S7-1200 System Manual, edition
   06/2015
 (11/23/2015) [109478148]

   11/2015, Product information, A5E03929122-AJ
For

   products:6ES7217-1AG40-0XB0, 6ES7212-1AE40-0XB0, 6E...

   more
   => CLICK HERE

Tuesday, November 17, 2015

IMPORTANT UPDATE 17 NOVEMBER 2015

PLEASE TAKE NOTE! PLEASE DISABLE AUTOMATIC WINDOWS UPDATE to avoid Windows10 to automatically install. This is to avoid INTERRUPTION to your current running system OR programming progress!

Please read for more information at Microsoft's Official Blog
( http://blogs.windows.com/windowsexperience/2015/10/29/making-it-easier-to-upgrade-to-windows-10/ )


Monday, November 2, 2015

UPDATE 02 NOVEMBER 2015

------------------------------------------------------------------------
#  Application example
------------------------------------------------------------------------

1. Migration of plants in SIMATIC (TIA Portal) - Visualization
 (10/27/2015) [76878921]

   A certain amount of know-how is required for migrating to new
   systems. Siemens supports you with many tools and other aids to get
   successfully into the TIA Portal and the new SIMATIC
   components.
For products:6AV6613-1XA01-1CE0,

   6AV2107-0GB00-0BB0, 6A...

   more
   => CLICK HERE
------------------------------------------------------------------------
2. Example blocks for WinCC V7 and STEP 7 V13 (TIA Portal) for S7-1200
   and S7-1500 in SCL
 (10/27/2015) [31624179]

   This documentation shows how WinCC V7.3 SE and TIA Portal STEP 7
   Professional V13 SP1 with example blocks is used for the solution
   of an technological automation task.
For

   products:6ES7211-1HD30-0XB0, 6ES7217-1AG40-0XB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
3. Migration of plants with SIMATIC (TIA Portal) - Controllers
 (10/28/2015) [83557459]

   A certain amount of know-how is required for migrating to new
   systems. Siemens supports you with many tools and other aids to get
   successfully into the TIA Portal and the new SIMATIC
   components.
For products:6ES7413-2XG00-0AB0,

   6ES7414-2XJ00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------

10. Configuration and application of PROFINET I-Device function
 (10/28/2015) [109478798]

   This entry explains the I-Device function and gives an overview of
   the various tasks that can be realized with it. These functions are
   explained in configuration and application examples.
For

   products:6ES7317-2FJ10-0AB0, 6ES7317-2FK14-0AB0, 6E...

   more
   => CLICK HERE

------------------------------------------------------------------------

1. PRONETA 2.2.0.18 Commissioning and Diagnostics Tool for PROFINET    10/21/2015
ID:67460624

During the setup phase of a PROFINET network, the correct configuration and wiring of the distributed IO is to be checked even before CPUs are integrated.
For products:6ES7153-2DA80-0XB0, 6ES7143-4BF50-0AA0, 6E...


=> CLICK HERE

------------------------------------------------------------------------
#  FAQ
------------------------------------------------------------------------

17. TIA Portal - An Overview of the Most Important Documents and Links
   - Safety
 (10/30/2015) [90939626]

   This site gives you an overview of the most important documents and
   links for the TIA Portal. Both newcomers and experienced TIA Portal
   users have an entry here to the essential information about the TIA
   Portal.
For products:6AV2103-0HA02-0UA0, 6AV2104-2FH03-0BJ0,

   6A...

   more
   => CLICK HERE
------------------------------------------------------------------------
18. Which communication services are supported by the CPUs with
   integrated PROFINET interface, the S7 software controller and by
   the WinAC RTX via Industrial Ethernet?
 (10/26/2015) [18909487]

   The table below shows, which devices support which communication
   services.
For products:6ES7317-7TK10-0AB0, 6ES7317-2FJ10-0AB0,

   6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
25. TIA Portal - An Overview of the Most Important Documents and Links
   - Controller
 (10/30/2015) [65601780]

   This site gives you an overview of the most important documents and
   links for the TIA Portal. Both newcomers and experienced TIA Portal
   users have an entry here to the essential information about the TIA
   Portal.
For products:6AV2107-0GB00-0BB0, 6AV2103-0HA02-0UA0,

   6A...

   more
   => CLICK HERE
------------------------------------------------------------------------
27. How do you use a hardware-independent clock with adjustable
   frequency in STEP 7 (TIA Portal)?
 (10/26/2015) [87507915]

   You want to use a clock that is hardware-independent, is processed
   synchronously and whose frequency can be set individually.
For

   products:6ES7822-1AA03-2YA6, 6ES7513-1AL00-0AB0, 6E...

   more
   => CLICK HERE
------------------------------------------------------------------------
34. Which rules have to be followed in STEP 7 V5.x and the TIA Portal
   when assigning the PROFINET device name?
 (10/26/2015) [109479534]

   The PROFINET device name is defined in the standard IEC 61158-6-10.
   To be able to communicate with PROFINET devices they have to be
   assigned names. These names are the device names in the Hardware
   Configuration. These device names must comply with the PROFINET
   name convention.
For products:6ES7822-1AA03-2YA6,

   6ES7810-4CC10-0KA5, 6E...